Storage / Cluster Fabric Optics RFQ

Does the N9336C quote include the CU2M cables, or only the switches?

Price-stripped RFQ for NetApp CLMSWITCH-24NODE-R5×4, Cisco N9336C (X190212-CS-PE)×4, copper/fiber cables, and SFP/QSFP lines from an AFF A70 fabric lot — not the 72-drive / ONTAP One pack story.

Quick Take

Quick Take: Freeze fabric CapEx as CLMSWITCH-24NODE-R5×4 + X190212-CS-PE (N9336C)×4, CU1M×4, CU2M×24, MPO×8, LC×16, SFP28×16, and both QSFP28 forms (X65405-N-C×8 + X65405 Ext×8). Do not omit CU2M while arguing switch stickers. Pack and ONTAP One math live only on the AFF A70 BOM page.

Procurement note: all money fields are stripped. Soft channel lead times for optics and Cisco support renewals are industry estimate / pending confirmation. This page is fabric-only — see the AFF A70 BOM article for 72-drive / ONTAP One Flash 1100 TB rows.

Definition: CLMSWITCH Marker vs N9336C Hardware

Quick Answer: A NetApp cluster-fabric RFQ freezes the CLMSWITCH marker, the Cisco N9336C chassis SKU, support/contract qty, and every copper/fiber/optic line before CapEx PO. It is not a drive-pack worksheet and not a single-HA drawer buy. Marker rows are entitlement signals — not physical switches by themselves.

Definition for CapEx: On NetApp CPQ exports, CLMSWITCH-24NODE-R5 is the cluster / SAN / storage switch marker for a 24-node-class fabric entitlement. X190212-CS-PE is the hardware line for Cluster Switch N9336C 12Pt PTSX 10/25/40/100G (Cisco Nexus 9336C-class). Buyers who quote only the Cisco chassis and drop the NetApp marker understate the equal-BOM brief; buyers who quote only the marker have no shippable hardware.

This page answers: how do I RFQ-check the N9336C fabric + optics + cabling CapEx from an AFF A70 lot without rehashing pack math? For 36 packs = 72 drives, ONTAP One Flash 1100 TB, and X50132A iWARP, use the sibling A70 BOM article in Related.

  • Fit this page: fabric-only equal-BOM — four switches, Cisco support/contract, full optics and cable counts.
  • Boundary: storage capacity ranking, ONTAP One TB meters, or single-HA C60 columns without a topology label.

Numbers Table: Switches×4 + Support + Optics Qty

Quick Answer: Line CLMSWITCH-24NODE-R5×4, X190212-CS-PE×4, HW support×4, DOC-CISCO-CONTRACT×4, then SFP28×16 and both QSFP28 forms (N-C×8 and Ext×8). Soft lead times stay industry estimate / pending confirmation. Switch stickers without optics or copper rows are not an equal fabric BOM for CapEx freeze.

Part numberProduct (short)QtyRFQ role
CLMSWITCH-24NODE-R5NetApp cluster switch marker (24-node)4Entitlement / fabric intent
X190212-CS-PECluster Switch N9336C 12Pt4Cisco hardware chassis
SVCVN-CON-SNT-9336CFX2-3HW SUPP 9336CFX2 / X190212, 8x5xNBD, 3–5Yr4Support qty only — no prices
DOC-CISCO-CONTRACTCisco Switch Service Contract4Contract qty only — no prices
X65404-N-CSFP28 25GbE SR1625GbE optic density
X65405-N-CQSFP28 100GbE SR,-C8NetApp -C optic form
X65405QSFP28 100GbE SRQty 1 / Ext 8Dual form — keep on RFQ

Verified from a 2026 AFF A70 CPQ export (price-stripped). Soft commercial windows for optics and Cisco renewals: industry estimate / pending confirmation — do not invent list or net amounts on the public brief.

Copper & Fiber Cabling Counts (Do Not Omit CU2M×24)

Quick Answer: The same lot ships X-QSFP-100G-CU1M-C×4, X-QSFP-100G-CU2M-C×24, OM4 MPO/MPO×8, and LC–LC OM4×16. CU2M×24 is the largest cable count and the easiest line to cut incorrectly when CapEx pressure hits switch stickers. Equal-BOM fabric RFQs keep every copper and fiber row visible.

Part numberProduct (short)QtyBuyer note
X-QSFP-100G-CU1M-CCisco QSFP–QSFP 100G CU Passive 1m4Short copper
X-QSFP-100G-CU2M-CCisco QSFP–QSFP 100G CU Passive 2m24Largest copper count — protect on RFQ
X66200-2-N-CCntlr–Switch OM4 MPO/MPO 2m8Controller-to-fabric fiber
X66250-2-N-CLC–LC OM4 2m16Lower-speed / host fan-out
X-02659-00-N-CRail Kit 4-Post Adj 24–322Install kit (often with switch racking)
X800-42U-R6-CJumper C13–C14 in-cab16Power cords — keep with PSU density on storage BOM
  • Do: put copper + fiber on the same RFQ cover sheet as N9336C×4 so peers cannot undercut by shipping “switch-only.”
  • Do not: accept a counter-quote that matches four chassis but zeros CU2M or MPO without a topology redesign note.

Pitfall: Mixing X65405 and X65405-N-C Forms

Quick Answer: The export lists X65405-N-C×8 and a bare X65405 line with Ext Qty 8. Treat Ext=8 for RFQ count on the bare SKU. Do not consolidate by deleting one form without written confirmation from the quoting desk — dual lines are a CapEx undercount trap, pending confirmation of packaging intent.

RFQ handling

  • Keep both part numbers visible on the equal-BOM brief.
  • Annotate “X65405 Ext Qty 8 ≠ Qty 1” so spreadsheet pivots do not collapse the row.
  • Ask whether -C and non -C are complementary optics pools or alternate packaging — mark the answer pending confirmation until signed.
  • Pair optic counts with SFP28×16 and the copper/fiber tables above so host 25GbE and 100GbE paths stay complete.

Own-route limitation: this checklist freezes SKU math from one CPQ lot. It does not replace Cisco Hardware Universe optic matrices, NetApp cabling guides for a specific ISL distance, or a site survey for rack power density.

Comparison: A70 Fabric vs A50 Fabric vs C60 No Fabric

Quick Answer: This A70-sourced fabric lot and typical A50 MCC-IP peers both show N9336C×4, but A70 uses X50132A iWARP while A50 uses X60134A. A single-HA C60 capacity column usually has zero cluster switches. Equalize switch + optics before CapEx ranking — prices stay off this page.

DimensionThis A70 fabric lotTypical A50 fabric peerTypical C60 single-HA
Cluster markerCLMSWITCH-24NODE-R5 × 4Often present ×4Often absent
Switch hardwareN9336C (X190212) × 4N9336C × 4Often 0
MCC-IP adapter (storage side)X50132A (A70)X60134A (A50)Often absent
Copper 2m CU24Peer-dependentN/A if no fabric
QSFP28 dual formsX65405-N-C + X65405 ExtVerify peer BOMN/A
Limitation of this pageDoes not size ISL distance, usable TB, or FC SAN directors — those need separate worksheets / peer pages.

When the peer is another large NX-OS fabric (for example Nexus 9336C-FX2 + 9364C-GX CWDM4 lots), keep optics families distinct — NetApp-coded X6540x rows are not interchangeable with arbitrary CWDM4 qty without redesign.

Fit / Unfit Decision Boundary

Quick Answer: Fit when CapEx funds MCC-IP or multi-HA cluster fabric with four N9336C switches and a full optics/cable kit. Unfit when the brief is a single-HA drawer, when procurement wants switch stickers only, or when the real question is drive-pack / ONTAP One TB (use the A70 BOM page instead).

Fit

  • Multi-HA AFF lots that already list CLMSWITCH×4 and N9336C×4
  • Buyers equalizing fabric CapEx across A70 and A50 peers (same switch count, different iWARP SKU)
  • Teams catching CU2M / dual QSFP undercounts before PO

Unfit

  • Single-HA C60 capacity buys with no fabric intent
  • Quotes that match four chassis but zero copper/fiber/optics without a redesign note
  • Readers looking for 72-drive pack math or ONTAP One Flash 1100 TB — that is the A70 BOM article

How To Freeze a Fabric-Only Equal-BOM RFQ

Quick Answer: Separate fabric from storage CapEx, line CLMSWITCH×4 with N9336C×4, attach Cisco support and contract qty, freeze CU1M/CU2M/MPO/LC counts, keep both X65405 forms plus SFP28×16, then equalize A50 and C60 peers and mark soft lead times as industry estimate / pending confirmation before the CapEx PO.

  1. Step 1 — Separate fabric CapEx from storage CapEx. Put switches, optics, and cables on this RFQ column. Send pack math and ONTAP One TB to the AFF A70 BOM checklist.
  2. Step 2 — Line CLMSWITCH markers and N9336C hardware. Require CLMSWITCH-24NODE-R5×4 and X190212-CS-PE×4 together. The marker is not a chassis substitute.
  3. Step 3 — Attach Cisco support and contract qty. Keep SVCVN-CON-SNT-9336CFX2-3×4 and DOC-CISCO-CONTRACT×4 as quantity-only lines — no public prices.
  4. Step 4 — Freeze copper and fiber cable counts. Line CU1M×4, CU2M×24, OM4 MPO×8, and LC×16. Reject “switch-only” counters that silently zero CU2M×24.
  5. Step 5 — Keep both QSFP28 optic forms plus SFP28. Quote X65405-N-C×8, X65405 Ext Qty 8, and X65404-N-C×16. Flag dual-SKU risk in writing.
  6. Step 6 — Equalize peers and mark soft lead times. Compare A50 fabric (same N9336C×4, X60134A) vs C60 no-fabric. Soft lead times = industry estimate / pending confirmation.

Frequently Asked Questions

Quick Answer: CLMSWITCH is the NetApp marker and X190212 is the N9336C chassis; keep both X65405 forms; never RFQ switches without CU2M×24 and optics; this page is fabric-only — pack/ONTAP One lives on the A70 article; equalize A50/C60 topology before CapEx ranking.

CLMSWITCH-24NODE-R5 is the NetApp cluster-switch marker (24-node class) that signals fabric entitlement on the CPQ. X190212-CS-PE is the Cisco N9336C 12-port hardware SKU. Quote both: marker×4 and switch×4. The marker alone is not a chassis.

The source BOM lists X65405-N-C×8 and a separate X65405 line with Ext Qty 8. Dropping either form undercounts optics CapEx. Confirm complementary versus alternate packaging with the quoting desk before PO; soft lead times remain industry estimate / pending confirmation.

No. An equal-BOM fabric RFQ must carry CU1M×4, CU2M×24, OM4 MPO×8, LC×16, SFP28×16, and both QSFP28 forms with the four switches. Omitting CU2M×24 while arguing switch stickers is the most common CapEx undercount on this lot.

No. This page freezes cluster-switch, optics, and cabling CapEx only. Pack math (36 packs = 72 drives), ONTAP One Flash 1100 TB, and X50132A iWARP live on the AFF A70 BOM article — link that page for the storage column.

A50 MCC-IP peers often also ship N9336C×4 but use X60134A iWARP, not A70 X50132A. A typical single-HA C60 capacity column has zero N9336C fabric. Equalize switch count and optics before any CapEx ranking; prices stay off this page.

References

Quick Answer: Cite NetApp MetroCluster IP required components for four IP switches, AFF A70/A90 cabling guidance, and Cisco Nexus 9300 / 9336C hardware documentation for optic and port context. Keep all benquan.hk peer pages in the Related appendix only — never duplicate those URLs here.

Key Takeaway

Key Takeaway: Quote fabric CapEx as CLMSWITCH×4 + N9336C×4 + CU2M×24 + dual X65405 forms + SFP28×16 — never switch stickers alone. Equalize A50 (same switches, different iWARP) vs C60 (often no fabric). BENQUAN GLOBAL LIMITED supplies NetApp cluster-switch and Cisco N9336C optics kits with competitive pricing.

Not sure your N9336C fabric optics BOM is locked?

If CLMSWITCH vs X190212, CU2M×24, or X65405 dual forms are still ambiguous before PO, click below for a free compatibility and delivery risk assessment.

Free Compatibility & Delivery Risk Assessment

Or call +852-21349834 · info@benquan.hk

Contents