Quick Take
Quick Take: AFF A50 is performance NVMe; AFF C60 is capacity flash (CF). A CPQ-aligned A50 lot ships 24× X4028A packs (= 48 drives), Flash 734 TB, X60134A×4, and four N9336C switches — not a peer of one C60 HA with 22 CF drives and 675 TB CF. Equalize topology first..
When AFF A50 vs AFF C60 Actually Matters
Quick Answer: Compare NetApp AFF A50 with AFF C60 when both lots stay on ONTAP all-flash hardware and the only open question is performance non-volatile memory express media versus capacity flash economics. It is the wrong page when you are standardized on ASA storage-area-network-only controllers or on FAS hybrid media.
- Use this page: Dual-path RFQ with an AFF A50 performance lot and an AFF C60 capacity lot on one brief.
- Not this page: FAS vs AFF — hybrid HDD/SSD vs all-flash media fork.
- Not this page: ASA vs PowerStore — SAN-only NetApp path vs Dell.
- Not this page: Pure FlashArray vs NetApp AFF — cross-vendor AFA peer.
- Ladder context: AFF A-Series specs & use cases — controller ladder when C-Series is out of scope.
Same ONTAP brand, different flash economics
A50 and C60 both run ONTAP, SnapMirror, and familiar ops. The fork is media class and licensed TB packaging — performance NVMe packs versus larger capacity-flash packs — plus whether you are buying a multi-node cluster or a single HA pair.
Platform Fork — Performance vs Capacity Flash
Quick Answer: NetApp AFF A50 uses performance drive packs, for example two 15.3TB non-volatile memory express self-encrypting drives. AFF C60r2 uses capacity-flash packs, for example two 30.7TB units. ONTAP Base software follows the media class, so the A50 is metered on Flash terabytes and the C60 on capacity-flash terabytes.
| Dimension | AFF A50 (perf) | AFF C60r2 (capacity) |
|---|---|---|
| Role | Latency-sensitive / higher IOPS flash | Higher TB density / capacity economics |
| Example drive pack | X4028A-2-A-C — 2×15.3TB NVMe4 SED | X4030A-CF-2-C — 2×30.7TB NVMe CF SED |
| ONTAP Base SKU family | SW-ONTAPB-FLASH-A50-C (per TB Flash) | SW-ONTAPB-CF-C60-C (per TB CF) |
| CPQ-aligned reference lot (2026-08-25) | AFF-A50-001×4; 24 packs = 48 drives; Flash 734 TB; X60134A×4; N9336C×4 | Single HA; 11 packs = 22 drives; CF 675 TB; no X60134A; no N9336C |
| Typical topology in peer lots | Four-node-class footprint + cluster / MCC-IP fabric | One HA system (two controllers) |
| Cluster fabric | CLMSWITCH-24NODE-R5×4 + X190212-CS-PE (N9336C)×4 | None on the single-HA C60 lot |
| MCC-IP back-end adapter | X60134A-C (2PT 100GbE iWARP)×4 | Absent — not an MCC-IP equal column |
| Encryption line | Often NO-DATA-ATREST-ENCRYPTION if SED packs still need OS flag clarity | Same — confirm SED vs software encryption path |
AFF A50 Reference BOM (Four-Node Class + Fabric)
Quick Answer: A CPQ-aligned performance lot (2026-08-25) uses AFF-A50-001×4, twenty-four X4028A-2-A-C packs (= 48 physical drives, not 24 SSDs), SW-ONTAPB-FLASH-A50-C at 734 TB, X60130/132/134/140 ×4 each (including X60134A iWARP), and four N9336C cluster switches. List and net prices omitted — RFQ for commercial terms.
Lot-level AFF A50 hardware (quantities from a price-stripped CPQ screenshot — do not treat as a public list):
| SKU | Description | Qty | Role |
|---|---|---|---|
| AFF-A50 | AFF A50, Model | 2 | Model marker |
| AFF-A50-001 | AFF A50 HA System (bundle) | 4 | Four-node-class HA footprint |
| AFF-A50A-100-C | AFF A50 HA System,-C | 2 | Chassis / HA system,-C |
| X4028A-2-A-C | Drive Pack 2×15.3TB NVMe4 SED,-C | 24 | 48 physical drives (24 packs × 2) |
| SW-ONTAPB-FLASH-A50-C | ONTAP Base Package, per TB, Flash, A50,-C | 734 | Licensed Flash TB (matches pack raw ≈48×15.3) |
| X60130A-C | I/O Module, 2PT, 100GbE,-C | 4 | Cluster / uplink |
| X60132A-C | I/O Module, 4PT, 10/25GbE,-C | 4 | Host Ethernet |
| X60134A-C | I/O Module, 2PT, 100GbE iWARP,-C | 4 | MetroCluster IP fabric adapter |
| X60140A-C | I/O Module, 4PT, FC Target+Init, 32G SFP,-C | 4 | FC host / tape adjacency |
| X5532A-N-C | Rail kit, 4-post thin,-C | 2 | Rack |
| X97602A-C | Power Supply, 1600W Titanium,-C | 4 | PSU |
| NO-DATA-ATREST-ENCRYPTION | No Data at Rest Encryption OS flag | 4 | Encryption policy line |
Cluster fabric (lot-level — four switches, not a single HA drawer):
| SKU | Description | Qty | Role |
|---|---|---|---|
| CLMSWITCH-24NODE-R5 | Switch, NetApp, Cluster / SAN / Storage, 24-Node | 4 | Cluster switch marker |
| X190212-CS-PE | Cluster Switch, N9336C 12Pt PTSX 10/25/40/100G | 4 | Cisco N9336C fabric |
| DOC-CISCO-CONTRACT | Cisco Switch Service Contract | 4 | Switch support paperwork |
Optics and copper appear on the same CPQ (QSFP 100G CU 1m/2m, OM4 MPO/LC, 100G SR4, SFP28 SR, QSFP28 SR) — freeze host-port matrix before cutting unused lines. Commercial list/net totals are never published on this page.
What this A50 lot implies
- Pack math: 24 × X4028A-2-A-C = 48 physical 15.3TB NVMe4 SED drives — never write “24 SSDs.” Raw ≈ 48×15.3 ≈ 734 TB aligns with SW-ONTAPB-FLASH-A50-C qty 734.
- MCC-IP fabric intent: X60134A-C×4 (100GbE iWARP) plus four N9336C switches is not a lone HA drawer — see the AFF A50 MCC-IP 24-disk floor worked example.
- Topology mismatch vs C60: four-node-class footprint + fabric vs one capacity HA — label this before any TCO ranking.
- Mixed host protocols: 100GbE, 10/25GbE, and 32G FC are all present; cut unused I/O only after the host matrix is frozen.
AFF C60 Reference BOM (Single HA Capacity)
Quick Answer: A CPQ-aligned capacity lot is one AFF C60r2 HA system with eleven X4030A-CF-2-C packs (= 22 physical drives), SW-ONTAPB-CF-C60-C at 675 TB, denser 10/25GbE modules, and no X60134A / N9336C fabric. It is not an MCC-IP equal column to the A50 lot. Commercial list totals omitted — RFQ for terms.
| SKU | Description | Qty | Role |
|---|---|---|---|
| AFF-C60 / AFF-C60-001 | AFF C60r2 Model / HA System (bundle) | 1 / 2 | Single HA pair markers |
| AFF-C60A-100-C | AFF C60r2 HA System,-C | 1 | Chassis / HA system |
| X4030A-CF-2-C | Drive Pack, NVMe SED CF, 2×30.7TB,-C | 11 | 22 physical CF drives (11 packs × 2) |
| SW-ONTAPB-CF-C60-C | ONTAP Base Package, per TB, CF, C60,-C | 675 | Licensed CF TB (matches ≈22×30.7) |
| X60130A-C | I/O Module, 2PT, 100GbE,-C | 2 | Uplink / HA interconnect adjacency |
| X60132A-C | I/O Module, 4PT, 10/25GbE,-C | 4 | Host Ethernet |
| X60140A-C | I/O Module, 4PT, FC Target+Init, 32G SFP,-C | 2 | FC |
| X60134A-C | I/O Module, 2PT, 100GbE iWARP,-C | 0 | Absent — not MCC-IP back-end on this lot |
| X190212-CS-PE / CLMSWITCH | N9336C / cluster switch markers | 0 | Single HA — no cluster fabric |
| X66211A-05-N-C | Cable, 100GbE QSFP28–QSFP28 Cu, 0.5m,-C | 2 | Short HA / interconnect copper |
| X66250-5-N-C | Cable, LC–LC, OM4, 5m,-C | 24 | Optical |
| X65404-N-C | SFP28, 25GbE, SR,-C | 16 | 25GbE optics |
| X5532A-N-C | Rail kit, 4-post thin,-C | 1 | Rack |
| X97602A-C | Power Supply, 1600W Titanium,-C | 2 | PSU |
| NO-DATA-ATREST-ENCRYPTION | No Data at Rest Encryption OS flag | 2 | Encryption policy line |
What this C60 lot implies
- 22×30.7TB CF SED drives (11 packs × 2) — higher raw density per drive than A50 15.3TB packs; validate workload suitability for capacity flash, not only TB math.
- 675 TB ONTAP Base CF on one HA pair — do not treat CF TB meters as interchangeable with Flash A50 734 TB without stating media class.
- No X60134A and no N9336C — this lot is a single-HA capacity column, not an MCC-IP dual-site peer to the A50 fabric build.
- Topology warning: ranking A50 (48 drives + 4 switches + iWARP) against this C60 HA without labeling the mismatch produces false “C60 cheaper” slides.
How to Equalize the RFQ
Quick Answer: State target usable capacity and the latency tier first, then choose AFF A50 performance media or AFF C60 capacity flash. Separately declare how many high-availability pairs are in scope and whether cluster switches are required. Only then compare ONTAP Base terabytes, input-output modules, optics, deployment service lines and quote validity.
| Equalize | A50 lot risk if ignored | C60 lot risk if ignored |
|---|---|---|
| Node / HA count | AFF-A50-001×4 + fabric looks “more expensive” vs one HA | Two controllers look “cheaper” but lack cluster / MCC-IP scale |
| Media class | Perf NVMe priced like capacity flash | CF sold into latency-critical VDI / OLTP |
| Drive pack math | 24 packs misread as 24 SSDs (true = 48 drives) | 11 packs = 22 drives — state pack×2 explicitly |
| ONTAP Base TB | Flash 734 TB vs CF 675 TB mixed on one TCO slide | Same |
| Cluster / MCC-IP fabric | N9336C×4 + X60134A×4 omitted from peer | Assumes free multi-HA / MCC growth without fabric |
| Host I/O | X60130/132/140 ×4 vs C60’s lighter I/O count | Same |
| Deploy services | Multi-system install under-scoped if peer is single HA | Under-scoped multi-system install |
Do not rank on EXW notes alone
Budgetary EXW figures on internal worksheets are not public list and are not a substitute for equal BOM. Freeze topology and media first; then dual-RFQ commercial terms under the same Incoterms and lead-time assumption.
Lead Time & August 2026 List Window
Quick Answer: Representative A50 and C60 configurations in mid-2026 often carry about 16 weeks delivery. Separately, NetApp list updates effective 15 August 2026 reprice open flash BOMs — read the dedicated uplift guide before you let either quote age past the effective date.
- Lead time: Plan rack, fabric, and cutover against ~16 weeks unless the channel confirms a shorter factory slot in writing.
- List uplift: NetApp Price Increase August 2026 — high-performance flash and capacity flash move on different percentage tracks; reprice both A50 and C60 lots if the quote crosses the effective date.
- Hybrid / Keystone adjacency: Hybrid / Keystone pressure — when CapEx flash is deferred into consumption models.
RFQ Checklist — A50 and C60 on One Brief
Quick Answer: One ONTAP brief with usable TB target, latency tier, and HA pair count → A50 performance line → C60 capacity line → equalize ONTAP Base TB, I/O, optics, cluster switches, PS-DEPLOY, lead time, and list-price validity date on both quotes.
What to put on the RFQ
- Media tier: performance NVMe (A50) vs capacity flash CF (C60) — state primary choice and alternate
- Topology: number of HA pairs; multi-node cluster yes/no
- Drive packs: SKU, drives per pack, SED, total drive count
- ONTAP Base: Flash A50 TB vs CF C60 TB on the same usable-capacity target
- I/O modules: 100GbE, 10/25GbE (2PT vs 4PT), 32G FC — host port matrix
- Optics / copper: QSFP 100G length, SFP28 SR qty, LC OM4 qty
- Cluster switches: N9336C (or equivalent) qty + Cisco/NetApp support paperwork
- Rails, PSUs, power cords, encryption OS flag
- Professional services: PS-DEPLOY-STD-ONTAP-M (or sized equivalent) per system
- Lead time assumption (e.g. 16 weeks) and quote validity vs August list window
- Incoterms (e.g. EXW) and destination — commercial only, not for public list publication
Submit the dual-path brief on rfq.html.
Which Part Numbers Should You Freeze on the RFQ (1 SKUs)?
Quick Answer: When quoting AFF C30 and sibling configurations across these 1 part numbers, lock the exact base MPN, redundant power supplies, optics, and matching 1-year or 3-year support tier on separate lines before comparing vendor discounts. Channel net pricing remains industry estimate / pending confirmation.
| Ordering SKU | Key Configuration & Boundary | Adjacent BOM Lines to Freeze |
|---|---|---|
AFF C30 | 2U 24 SSD slots, dual HA controllers, 128 GB, ONTAP 9.16.1+, C-Series QLC. Not C60 and not A50. | AFF C30 HA pair, QLC SSD PIDs per HWU, 100GbE / 25GbE / FC per drawing, NS224 when growth is drawn |
Frequently Asked Questions
Quick Answer: NetApp AFF A50 wins latency-sensitive workloads on performance media, while AFF C60 wins on capacity-flash density. Equalize high-availability pair count, ONTAP Base media class and cluster fabric before ranking total cost of ownership. Confirm the roughly sixteen-week lead time and the August 2026 list validity on every commercial quote.
Neither is universal. Pick A50 for performance NVMe workloads and C60 for capacity-flash economics. Equalize usable TB, latency tier, and node topology before ranking.
Only if you label the topology mismatch. A CPQ A50 lot with AFF-A50-001×4, 48 drives, X60134A×4, and four N9336C switches is not a peer of a single C60 HA with 22 CF drives and no fabric. Normalize growth plan or quote both as explicit options.
No. SW-ONTAPB-FLASH-A50-C and SW-ONTAPB-CF-C60-C follow different media families. State media class when you compare licensed TB.
Plan about 16 weeks for representative mid-2026 A50 / C60 configurations unless your channel confirms a shorter slot in writing.
Submit one RFQ with media, drive packs, ONTAP Base TB, I/O, switches, and deploy services.
Key Takeaway
Key Takeaway: AFF A50 vs AFF C60 is a performance-NVMe versus capacity-flash ONTAP fork — and the CPQ peer lots mismatch topology (48 drives + X60134A + four N9336C vs 22 CF drives, no fabric). Freeze pack math (24 packs ≠ 24 SSDs), media class, and fabric before ranking. BENQUAN GLOBAL LIMITED supplies NetApp AFF A50 and AFF C60 with competitive pricing.