Storage / Lifecycle

DM7000F End of Support Nov 30: Should You Renew Post-Warranty or Refresh DM7000F (7Y40) and DM7000H (7Y56) to DM7100/DM7200?

Lenovo ThinkSystem DM7000F (7Y40) and DM7000H (7Y56) reach End of Support on 2026-11-30. Compare post-warranty renewal vs refresh to DM7100 or DM7200F.

Quick Take

Quick Take: On 2026-11-30, Lenovo ThinkSystem DM7000F (machine type 7Y40) and DM7000H (machine type 7Y56) reach End of Support—not End of Marketing, which passed years ago. Always re-verify your serial number and geo in Lenovo's End of Service Date Lookup. Because DM7100F (7D25) was withdrawn on 2025-11-30, all-flash refreshes should evaluate DM7200F (7DJ3).

Definition: In Lenovo storage lifecycle management, Withdrawal from Marketing (End of Sale) is defined as the last date a machine type can be ordered new from Lenovo manufacturing, whereas End of Support / End of Service (EOS) refers to the date after which Lenovo ceases standard hardware maintenance and software support obligations for that machine type unless a region-specific exception applies.

What does 2026-11-30 mean for Lenovo ThinkSystem DM7000F (7Y40) and DM7000H (7Y56)?

Quick Answer: November 30, 2026 (2026-11-30) is the End of Support (End of Service) milestone for the ThinkSystem DM7000F (machine type 7Y40) all-flash array and DM7000H (machine type 7Y56) hybrid array—not the withdrawal-from-marketing date. Both systems are already withdrawn from new sales, so buyers must re-confirm serial-level dates in Lenovo's End of Service Date Lookup.

First, clarify the exact lifecycle milestone so your team does not confuse an ordering cutoff with a support termination. November 30, 2026 (2026-11-30) is the End of Support / End of Service (EOS) date for the Lenovo ThinkSystem DM7000F Unified Flash Storage Array (Machine Type 7Y40) and the Lenovo ThinkSystem DM7000H Unified Hybrid Storage Array (Machine Type 7Y56). It is not the new-order cutoff: per Lenovo Press product guides LP0912 and LP0886, both 7Y40 and 7Y56 were withdrawn from marketing years earlier.

Because Lenovo states on its official End of Service Date Lookup for Servers/Storage/Networking products (support.lenovo.com/us/en/solutions/endofservice / datacentersupport.lenovo.com) that announced EOS dates can vary by geographic region (NA, LA, EMEA, AP, or the PRC EOS Announcement Report), every infrastructure team should re-verify its exact machine type (7Y40 or 7Y56), model (CTO1WW), and serial numbers in the official lookup portal before freezing Q4 2026 budgets.

Lenovo's published EOS lookup policy also notes two important operational rules:

  • Five-year historical baseline: Lenovo has historically provided service and support for at least 5 years (60 months) following a product's withdrawal from marketing, subject to parts and skilled resource availability by region.
  • Commercial endeavors beyond EOS: Lenovo states that in some cases it may use reasonable commercial endeavors to maintain eligible products beyond the announced EOS date, but such extensions are never guaranteed and depend on local spare parts inventory.

What are the verified specifications of DM7000F (7Y40) and DM7000H (7Y56) on Lenovo Press?

Quick Answer: Per Lenovo Press LP0912 and LP0886, both DM7000F (7Y40) and DM7000H (7Y56) use a 3U dual-controller enclosure with 256 GB RAM and 16 GB battery-backed NVRAM per HA pair. DM7000F scales to 384 SAS SSDs (5.89 PB), while DM7000H adds 4 TB NVMe Flash Cache and scales to 480 drives (7.68 PB).

Before you request a support bridge or size a replacement array, pull the baseline hardware and ONTAP specifications of your installed 7Y40 or 7Y56 estate from Lenovo Press LP0912 (DM7000F) and LP0886 (DM7000H). No prices are published here; any cost figure must be confirmed in a written quotation.

Specification ThinkSystem DM7000F (LP0912) ThinkSystem DM7000H (LP0886)
Controller machine type & CTO base 7Y40 (7Y40CTO1WW, feature B38K, controller B39H) 7Y56 (7Y56CTO1WW, feature B38K, controller B39H)
Controller enclosure form factor 3U rack mount (dual active-active HA pair) 3U rack mount (dual active-active HA pair)
System memory & NVRAM (per HA pair) 256 GB RAM (128 GB/ctrl) + 16 GB mirrored NVRAM (8 GB/ctrl) 256 GB RAM (128 GB/ctrl) + 16 GB mirrored NVRAM (8 GB/ctrl)
Onboard NVMe Flash Cache None (all-flash array) 4 TB NVMe Flash Cache (2 TB per controller)
HA / cluster interconnect ports 4x 10 GbE SFP+ (2 ports per controller) 4x 10 GbE SFP+ (2 ports per controller)
Base host ports (per 3U enclosure) 8x 1/10 GbE or 4/8/16 Gb FC SFP+ plus 4x 1/10 GbE RJ-45 8x 1/10 GbE or 4/8/16 Gb FC SFP+ plus 4x 1/10 GbE RJ-45
Optional adapter card host ports 10 GbE, 40 GbE QSFP+, 25 GbE iWARP (MCC-IP), 8/16/32 Gb FC 10 GbE, 40 GbE QSFP+, 25 GbE iWARP (MCC-IP), 8/16/32 Gb FC
Supported expansion enclosures Up to 16x DM240S 2U24 SFF (7Y58, 7D7Y) via 12 Gb SAS Up to 480 drives across DM240S (7Y58), DM120S (7Y59), DM600S (7Y43)
Max drives & max raw capacity Up to 384 SFF 12 Gb SAS SSDs / up to 5.89 PB raw Up to 480 LFF/SFF drives / up to 7.68 PB raw
Max random read performance (LP0912/LP0886) Up to 350,000 random read IOPS (8 KB blocks) Up to 350,000 random read IOPS (8 KB blocks)
Power supplies (3U controller enclosure) 2x redundant hot-swap 1460 W Platinum AC (IEC 320-C14) 2x redundant hot-swap 1460 W Platinum AC (IEC 320-C14)

Notice a critical detail in the LP0886 Change History (September 12, 2023 update): Lenovo removed 7D7X, 7D7Y, and 7D7Z expansion machine types from the DM7000H (7Y56) supported list, leaving 7Y58 (DM240S 2U24), 7Y59 (DM120S 2U12), and 7Y43 (DM600S 4U60) with 1-year warranty machine types. Always check the actual machine type label on every attached expansion shelf.

Which same-family models replace DM7000F and DM7000H: DM7100F/H (7D25/7D26) or DM7200F (7DJ3)?

Quick Answer: Lenovo Press LP0912 and LP0886 originally named DM7100F (7D25) and DM7100H (7D26) as replacements. However, Lenovo Press LP1271 states that DM7100F (7D25) was itself withdrawn from marketing on 2025-11-30. For new all-flash refreshes in late 2026, evaluate the active 2U all-NVMe ThinkSystem DM7200F (7DJ3, LP2075) alongside DM7100H (7D26) for hybrid estates.

When Lenovo withdrew the DM7000F and DM7000H, Lenovo Press LP0912 and LP0886 pointed buyers to the ThinkSystem DM7100F (7D25, LP1271) and ThinkSystem DM7100H (7D26, LP1270). However, a thorough 2026 procurement check reveals an important generation shift:

  • DM7100F (7D25) is now also withdrawn from marketing: According to the January 12, 2026 update in Lenovo Press LP1271, the ThinkSystem DM7100F was withdrawn from marketing on November 30, 2025 (2025-11-30). While existing DM7100F units remain in their support lifecycle, new all-flash replacement RFQs in late 2026 should not specify 7D25 for new factory builds.
  • DM7200F (7DJ3) is the current all-NVMe flash target: Lenovo Press LP2075 (updated October 26, 2026 for ONTAP 9.19) documents the ThinkSystem DM7200F (7DJ3, 7DJ3CTO1WW), a 2U all-NVMe unified array with 24 onboard NVMe bays, 256 GB RAM, 32 GB NVMEM, up to 120 NVMe SSDs via DM242N (7DJ8) 100 GbE expansion shelves, and up to 139% higher performance than the DM7100F.
  • DM7100H (7D26) for hybrid LFF/SFF workloads: Lenovo Press LP1270 lists the 4U ThinkSystem DM7100H (7D26, 7D26CTO1WW) with 256 GB RAM, 32 GB NVRAM, 4 TB NVMe Flash Cache, and up to 720 drives (10.95 PB) across DM240S (7Y58/7D7Y), DM120S (7Y59/7D7X), and DM600S (7Y43/7D7Z) SAS expansion enclosures. Confirm regional CTO orderability of 7D26 or evaluate tiering cold data from an all-NVMe DM7200F (7DJ3) or DM5200F (7DJ2) using ONTAP FabricPool.
Attribute DM7000F (7Y40) / DM7000H (7Y56) DM7100F (7D25) / DM7100H (7D26) DM7200F (7DJ3, LP2075)
Marketing status (Oct 2026) Withdrawn; EOS 2026-11-30 DM7100F withdrawn 2025-11-30 (LP1271); DM7100H per LP1270 Active all-NVMe family (LP2075 updated 2026-10-26)
Controller form factor 3U controller enclosure (no internal drives) 4U controller enclosure (no internal drives) 2U controller + 24 onboard NVMe SFF bays
Memory & NVRAM per HA pair 256 GB RAM + 16 GB NVRAM 256 GB RAM + 32 GB NVRAM 256 GB RAM + 32 GB NVMEM
Drive media & expansion shelf 12 Gb SAS (DM240S 7Y58, DM120S 7Y59, DM600S 7Y43) NVMe (DM240N 7Y62) or 12 Gb SAS (DM240S/120S/600S) End-to-end NVMe (DM242N 7DJ8 via 100 GbE RoCE)
Max drives per HA pair 384 SAS SSDs (DM7000F) / 480 drives (DM7000H) 96 NVMe or 480 SAS SSDs (DM7100F) / 720 drives (DM7100H) Up to 120 NVMe SED SSDs (1.92 TB to 15.36 TB)
Host Fibre Channel speeds 4/8/16 Gb FC base; optional 8/16/32 Gb FC cards 4/8/16 Gb FC mezz; optional 8/16/32 Gb FC cards 16/32/64 Gb FC HICs (4-port SFP+)
Host Ethernet speeds 1/10 GbE base; optional 10/40 GbE, 25 GbE iWARP 25 GbE mezz; optional 10GBASE-T, 10/25/40/100 GbE 10GBASE-T, 10/25 GbE SFP28, 40/100 GbE QSFP28 & Crypto
Power supplies (base enclosure) 2x 1460 W Platinum AC (100–240 V) 4x 1600 W Platinum AC (100–240 V) 2x 1600 W Titanium AC (200–240 V on DM7200F)

End of Marketing vs End of Support, and Post-Warranty Extension vs Hardware Refresh: how do they compare?

Quick Answer: Withdrawal from marketing stops new factory system orders, whereas End of Support (2026-11-30) ends standard vendor service obligations unless a commercial post-EOS bridge is approved by Lenovo for your geo. A short-term bridge buys migration time, while a refresh to DM7200F (7DJ3) moves the estate to end-to-end NVMe and 64 Gb FC.

Storage owners often ask whether they can simply renew maintenance on a 7Y40 or 7Y56 past 2026-11-30 or whether they must replace the hardware immediately. Compare the two paths across five procurement criteria:

Decision Factor Path A: Short-Term Post-EOS Support Bridge (Renew) Path B: Same-Family Hardware Refresh (DM7200F 7DJ3 / DM7100H 7D26)
Primary goal Buy 3 to 12 months of cutover time during a data center migration or budget freeze Replace aging 3U SAS-based controllers before standard vendor support ends on 2026-11-30
Vendor obligation Discretionary: Lenovo states post-EOS maintenance is subject to regional parts and commercial endeavor Full 3-year to 5-year Foundation, Essential (24x7 4-hour), or Premier Support warranty
ONTAP software track Frozen on legacy supported ONTAP releases (LP0912/LP0886 list ONTAP 9.7–9.11 selections) Supports current ONTAP 9.16 through ONTAP 9.19 (LP2075 updated 2026-10-26) with ARP anti-ransomware
Shelf & media reuse Keeps existing 12 Gb SAS drives and 7Y58/7Y59/7Y43 shelves in place DM7200F (7DJ3) uses internal U.2 NVMe + DM242N (7DJ8) 100 GbE shelves; data migrates via SnapMirror
Facility & rack impact Zero rack change (keeps 3U controller + 2U/4U SAS shelves) Consolidates multiple 12 Gb SAS shelves into a 2U 24-bay NVMe base (7DJ3, 200–240 V Titanium PSUs)

How do you prepare a DM7000F/H to DM7100/DM7200 refresh or renewal RFQ in six steps?

Quick Answer: Collect 7Y40 and 7Y56 serial numbers, verify regional EOS dates in Lenovo's lookup portal, inventory attached 12 Gb SAS expansion shelves (7Y58, 7Y59, 7Y43), audit host FC and Ethernet port speeds, verify ONTAP software bundle and encryption rules, and issue a split RFQ comparing a short migration bridge against a new DMSeries array.

Follow this six-step engineering and procurement checklist to build a clean renewal-vs-refresh RFQ before 2026-11-30:

  1. Step 1 — Export controller and shelf serial numbers and MTMs: Record the exact 4-character machine type (7Y40 for DM7000F, 7Y56 for DM7000H) and serial numbers for both the 3U controller enclosure and every attached expansion enclosure (7Y58 DM240S, 7Y59 DM120S, 7Y43 DM600S).
  2. Step 2 — Verify your Geo EOS date in Lenovo's official lookup: Run each machine type and model in the Lenovo End of Service Date Lookup for your region (NA, EMEA, AP, LA, or PRC report) and save a dated screenshot for your compliance file.
  3. Step 3 — Audit expansion shelf media and usable capacity: Check whether your capacity sits on 12 Gb SAS SSDs (960 GB to 15.36 TB in DM240S) or NL SAS HDDs (4 TB to 16 TB in DM120S/DM600S). Remember that the all-NVMe DM7200F (7DJ3) has a 68 TB minimum capacity per HA pair (minimum 8 NVMe drives) and uses DM242N (7DJ8) 100 GbE RoCE shelves rather than 12 Gb Mini-SAS HD SFF-8644 shelves.
  4. Step 4 — Map host protocol ports and transceiver speeds: Count your active FC and Ethernet ports on the 7Y40/7Y56 (10 GbE RJ-45/SFP+, 40 GbE QSFP+, or 8/16/32 Gb FC). When quoting a DM7200F (7DJ3), note that host connectivity uses up to 6 Host Interface Cards (HICs) per HA pair (4XC7A97031 64/32Gb 4-port FC, 4XC7A97035 10/25Gb 4-port Ethernet, 4XC7A97033 100Gb 2-port Ethernet, or 4XC7A97032 10GBASE-T), and Ethernet SFPs on DMx200F run at posted speed only without dual-rate auto-negotiation.
  5. Step 5 — Check ONTAP bundle and encryption feature codes: On DM7000F/H, software was sold as Unified Base (B5RH, China only) or Unified Premium (B5RJ), with separate encryption (BAYL/BF5Q/BKFB/BNM2/BRJW) and non-encryption (BAYK/BF5R/BKFA/BNM1/BRJX) codes. On DM7200F (7DJ3), choose between Unified Essentials (BWU9) and Unified Complete (BWU8, which includes SnapMirror, SnapVault, SnapCenter, SnapLock, and Autonomous Ransomware Protection) and select the matching ONTAP 9.16–9.19 encryption (CKJZ) or non-encryption (CKK0) code for your market.
  6. Step 6 — Issue a dual-track RFQ (Bridge vs Refresh): Ask authorized channels to quote Option A (any Lenovo-approved post-EOS support extension window available for your serials) alongside Option B (a new ThinkSystem DM7200F 7DJ3, DM5200F 7DJ2, or hybrid equivalent with SnapMirror migration).

What are the typical deployment scenarios and use cases for renewing vs refreshing DM7000 arrays?

Quick Answer: Four enterprise storage scenarios dominate DM7000 lifecycle planning: core SAN/NAS consolidation refreshing from DM7000F (7Y40) to all-NVMe DM7200F (7DJ3), high-capacity hybrid archives on DM7000H (7Y56) with 4U60 LFF shelves, SnapMirror or MetroCluster pairs requiring matched ONTAP versions, and short 6-to-12-month data center exit bridges.

Here are four typical enterprise deployment scenarios and use cases where storage teams must choose between a short extension and a full DM Series refresh:

  • Scenario 1 — High-IOPS SAN / VMware / database consolidation on DM7000F (7Y40) refreshing to DM7200F (7DJ3): An enterprise running 100 TB to 500 TB of all-flash SAS SSDs across a 3U 7Y40 and multiple 2U DM240S shelves can consolidate into a 2U DM7200F (7DJ3) with 24 onboard NVMe drives (up to 15.36 TB per NVMe SED drive) and 32/64 Gb FC or 25/100 GbE host HICs, cutting rack space while moving to end-to-end NVMe.
  • Scenario 2 — Petabyte-scale hybrid NAS/SAN archive on DM7000H (7Y56) with DM600S 4U60 LFF shelves: A hospital, bank, or manufacturer using 4 TB to 16 TB NL SAS HDDs in 7Y43 4U60 enclosures behind a 7Y56 controller should separate hot working sets (migrated to all-NVMe DM7200F or DM5200F) from cold archive data (tiered via ONTAP FabricPool to S3 object storage or a hybrid array).
  • Scenario 3 — SnapMirror DR or MetroCluster IP pairs spanning two sites: Because ONTAP scale-out clusters and MetroCluster IP have version and platform interoperability rules (checked in the Lenovo Storage Interoperation Center, LSIC), refreshing only one side of a 7Y40 HA pair requires verifying ONTAP 9.11-to-9.16/9.19 SnapMirror compatibility before cutover.
  • Scenario 4 — Short 6-month bridge before a scheduled 2027 data center relocation: Where a facility move is already locked for mid-2027, buying a new storage array into the old rack may be impractical; here, teams request a serial-specific post-EOS support availability check from Lenovo while ordering the new 7DJ3 array directly into the target data hall.

Who is this guide for, and who is it not for?

Quick Answer: Storage architects, infrastructure leads, and procurement teams running Lenovo ThinkSystem DM7000F (7Y40) or DM7000H (7Y56) arrays approaching the 2026-11-30 End of Support milestone will use these checks directly. It does not serve readers looking for fabricated list prices, unverified third-party SLA promises, or claims of reseller-program status.

Useful for:

  • Enterprise storage and SAN/NAS managers running Lenovo ThinkSystem DM7000F (7Y40) or DM7000H (7Y56) arrays approaching 2026-11-30
  • Procurement teams comparing a post-warranty support bridge against a refresh to ThinkSystem DM7200F (7DJ3), DM5200F (7DJ2), or DM7100H (7D26)
  • Architects who need an exact checklist of machine types, shelves, host HICs, and ONTAP bundle codes (BWU8 vs BWU9) before releasing an RFQ

Not for:

  • Readers looking for published list or street prices (all pricing is by written quotation only)
  • Buyers who want to plug legacy 12 Gb SAS DM240S shelves directly into an all-NVMe DM7200F controller as NVMe expansion (use ONTAP SnapMirror to migrate data instead)
  • Readers seeking reseller-program status claims; BENQUAN GLOBAL LIMITED supplies Lenovo hardware sourced through authorized channels and states no programme affiliation for Lenovo

Frequently Asked Questions

November 30, 2026 (2026-11-30) is the End of Support / End of Service (EOS) date for ThinkSystem DM7000F (7Y40) and DM7000H (7Y56), not the End of Sale date. Both models were already withdrawn from marketing earlier. Always re-confirm your specific geo and serial numbers in Lenovo's End of Service Date Lookup.

Per Lenovo Press LP0912 and LP0886, the DM7000F controller enclosure is machine type 7Y40 (7Y40CTO1WW) and the DM7000H controller enclosure is machine type 7Y56 (7Y56CTO1WW). Expansion enclosures are 7Y58 / 7D7Y for the DM240S 2U24 SFF shelf, 7Y59 for the DM120S 2U12 LFF shelf, and 7Y43 for the DM600S 4U60 LFF shelf.

For new all-flash purchases in late 2026, evaluate the ThinkSystem DM7200F (7DJ3, Lenovo Press LP2075). While LP0912 originally listed the DM7100F (7D25) as the replacement, Lenovo Press LP1271 notes that the DM7100F was withdrawn from marketing on November 30, 2025 (2025-11-30). The DM7200F (7DJ3) is the current 2U all-NVMe model and is rated up to 139% faster than the DM7100F.

No. The DM7000F uses 12 Gb SAS expansion (Mini-SAS HD SFF-8644) to DM240S shelves, whereas the DM7200F (7DJ3) is an end-to-end NVMe system that houses 24 NVMe SSDs in the 2U base enclosure and expands via 100 GbE RoCE to DM242N (7DJ8) NVMe enclosures. You migrate volumes across generations over the network using ONTAP SnapMirror.

First, check rack power: DM7000F/H 3U enclosures use 100–240 V power supplies, whereas the DM7200F (7DJ3) 1600 W Titanium power supplies require 200–240 V AC (only the smaller DM3200F supports 100–120 V). Second, check host optics: Ethernet SFPs on DM7200F HICs run at posted speed only and do not support dual line-rate auto-negotiation.

Standard support ends at the EOS milestone. Lenovo's EOS lookup states that in some cases Lenovo will use reasonable commercial endeavors to maintain eligible products beyond EOS depending on regional spare parts and resource availability. Submit your serial numbers and target bridge months to verify whether a short post-EOS extension is quotable in your region.

Key Takeaway

Key Takeaway: Treat 2026-11-30 as the End of Support boundary for Lenovo ThinkSystem DM7000F (7Y40) and DM7000H (7Y56). Confirm every serial in Lenovo's EOS lookup, audit 12 Gb SAS shelves and FC/Ethernet ports before quoting DM7200F (7DJ3) or DM7100H (7D26), and avoid unverified pricing. BENQUAN GLOBAL LIMITED supplies Lenovo storage sourced through authorized channels.

Request a quote

Send your 7Y40 or 7Y56 serial numbers, attached expansion shelf machine types, active FC/Ethernet port counts, usable TB, and ONTAP software bundle (Essentials vs Complete). We will return a written quotation comparing any eligible post-EOS bridge against a ThinkSystem DM7200F (7DJ3) or hybrid refresh BOM.

Free Compatibility & Delivery Risk Assessment

BENQUAN GLOBAL LIMITED supplies Lenovo ThinkSystem storage arrays, expansion enclosures, and servers sourced through authorized channels at competitive pricing; every price is confirmed only in a written quotation.

Email an RFQ to info@benquan.hk · RFQ form · Lenovo SKU Lookup

All prices are by written quotation only; any figure not confirmed in writing is an industry estimate, pending confirmation.

Or call +852-21349834 · info@benquan.hk

Contents