Quick Take
Quick Take: A tender BOM that says "servers, switches, storage" buys you three different kits and a price comparison that means nothing. Write 9 fields on every line — function, performance floor, quantity with units, interfaces and optics, licence term, power and cooling, warranty, delivery window, acceptance test — add a deviation table, and ask for one alternative column. Then bids differ in price and delivery, not in what is being bought.
You are not writing paperwork. You are deciding what the evaluation committee will be able to compare. Spend two hours on the BOM now, or spend a tender round re-running it later. Send us the draft clauses and we will mark the lines that will come back incomparable, before the tender opens.
Key extractable numbers
ConnectX generation gate on this page (checked 2026-10-23): ConnectX-7 up to 400 Gb/s on PCIe Gen5-class hosts; ConnectX-8 SuperNIC up to 800 Gb/s with PCIe Gen6 path (datasheet up to 48 lanes). Example CX8 OPNs: C8180 900-9X81E-00EX-ST0 (OSFP; 800G XDR IB / 2×400GbE) and C8240 900-9X81Q-00CN-ST0 (dual QSFP112; 400GbE / NDR IB defaults). Lock hop rate, switch/optics, PCIe, and cage before lead-time order—800G NIC on a 400G fabric is CapEx waste.
What goes wrong when the RFQ says “next-gen NIC” without a rate?
Quick Answer: You pay for 800G ports that never leave 400G paths — or you underspec and redo the fabric mid-build.
Typical scene: the GPU quote lists ConnectX-8 because the brochure says 800 Gb/s. The leaf switches on the same BOM are still 400G NDR. Optics kits are QSFP112 400G. Servers ship with PCIe Gen5 risers. After cutover the cluster runs — but CapEx bought a generation the fabric cannot use. This is a typical scenario, not a named customer.
Existing guides cover ConnectX-7 vs Broadcom and “order NICs before GPUs.” This page answers only the generation gate: stay on ConnectX-7 at 400 Gb/s, or move to ConnectX-8 at 800 Gb/s.
Official rates and RFQ OPN examples (checked 2026-10-23)
Quick Answer: 800 vs 400 Gb/s is the headline; cage and PCIe decide whether you can use it.
| Item | ConnectX-7 | ConnectX-8 SuperNIC |
|---|---|---|
| Max throughput (NVIDIA adapters page) | Up to 400 Gb/s | Up to 800 Gb/s |
| Host interface (typical) | PCIe Gen5 class designs | PCIe Gen6 (datasheet: up to 48 lanes) |
| Example OPNs | Project-specific MCX7 lines | C8180 900-9X81E-00EX-ST0 (OSFP); C8240 900-9X81Q-00CN-ST0 (dual QSFP112) |
| Default port story (CX8 manual) | n/a | C8180: 800G XDR IB / 2×400GbE; C8240: 400GbE / NDR IB defaults |
| When it wins the RFQ | 400G fabric + Gen5 hosts | 800G/XDR or CX8-called multi-plane + Gen6 path |
Figures from NVIDIA public adapters page, ConnectX-8 datasheet and user manual OPN table — pending confirmation against your dated quote and firmware profile. ConnectX-9 (up to 1.6 Tb/s) is a later decision, not a silent substitute on this RFQ.
What “need ConnectX-8” means for procurement
Quick Answer: The architecture requires a rate or host path CX7 cannot provide — not that CX8 exists.
Definition: for buying, you need ConnectX-8 when at least one locked design constraint — link rate (e.g. 800G InfiniBand XDR), platform reference (fabric docs that name ConnectX-8), or host PCIe Gen6 path — cannot be met by ConnectX-7’s 400 Gb/s class. If none of those constraints exist, “need” is marketing, not a BOM rule.
Like specifying a dual-axle truck only when the route has a weight limit the single-axle cannot pass. Same cargo, different gate.
Lock CX7 vs CX8 on the RFQ, 6 steps
Quick Answer: Hop rates → switch/optics → PCIe → cage/OPN → one generation per plane → then lead-time order.
- Step 1 — Write the target rate on every hop — Leaf–GPU, leaf–spine, storage — each link gets a Gb/s number from the architecture, not from marketing.
- Step 2 — Check switch and optics generation — If the switch ASIC and optics stop at 400G, an 800G NIC does not create 800G fabric.
- Step 3 — Check host PCIe generation — CX8 datasheet assumes Gen6. Gen5 hosts → keep CX7 or redesign the server.
- Step 4 — Pick cage and OPN together — OSFP (e.g. C8180) vs dual QSFP112 (e.g. C8240) drives cable and transceiver SKUs.
- Step 5 — Freeze one NIC generation per plane — Document CX7-only or CX8-only on the RFQ so bidders cannot mix silently.
- Step 6 — Then sequence lead times — After the generation is locked, order long-lead NICs/optics before GPUs — see the companion order-first note.
Small first step: highlight the NIC line on your best BOM. If it does not say 400 or 800 and the cage type, rewrite that cell before comparing price.
Who must move to CX8 — who should stay on CX7?
Quick Answer: XDR/800G or Gen6 platform: CX8. Mature 400G NDR/RoCE on Gen5: CX7.
New AI factory plane targeting 800G InfiniBand XDR. C8180-class OSFP paths and matching switches/optics belong on the first RFQ. Ordering CX7 “to save” forces a mid-project forklift.
Expansion of an existing 400G NDR or RoCE pod on Gen5 servers. Stay on ConnectX-7 unless the expansion document changes the rate. Mixing one CX8 rack into a CX7 plane creates spare-part debt.
- Fit: multi-vendor GPU server RFQs naming SuperNIC/HCA; fabric refresh where switch SKUs already say 800G; dual-path quotes that must show CX7 and CX8 columns.
- Not fit: single workstation NIC; storage-only Ethernet under 100G; buyers who only need BlueField offload (separate guide).
Generation traps on NIC RFQs
Quick Answer: 800G NIC on 400G fabric; Gen6 card in Gen5 slot; silent OPN swaps.
| Trap | What happens | Fix |
|---|---|---|
| Award CX8 into 400G-only BOM | Paid bandwidth unused | Match switch + optics first |
| Ignore PCIe generation | Host bottleneck | Require Gen6 for CX8 lines |
| OSFP quote, QSFP112 install | Cables/optics mismatch | Freeze cage on RFQ |
| Mix CX7 and CX8 spars | Ops cost spike | One generation per plane |
| Substitute CX9 silently | Unplanned CapEx/optics | Name max generation allowed |
| No lead-time after pick | Dark racks | Order NICs/optics before GPUs |
Frequently Asked Questions
Quick Answer: A tender BOM is the issuer's pricing baseline: same lines, same units, same licence years. Bidders answer with a deviation table, and the committee compares lines, not totals.
NVIDIA’s InfiniBand adapters page (checked 2026-10-23) rates ConnectX-8 SuperNIC up to 800 Gb/s and ConnectX-7 up to 400 Gb/s. ConnectX-9 is listed separately at up to 1.6 Tb/s — out of scope for this decision.
When the design needs a single-link or platform path that CX7 cannot serve: InfiniBand XDR at 800 Gb/s, Ethernet multi-plane designs that call for ConnectX-8, or hosts that expose PCIe Gen6 paths the BOM already locks. If every hop is still 400G NDR/Ethernet and the server is Gen5, CX7 usually remains the RFQ baseline.
Common mass-production examples from the ConnectX-8 user manual: C8180 SKU 900-9X81E-00EX-ST0 (single OSFP cage; default 800G XDR InfiniBand / 2×400GbE) and C8240 SKU 900-9X81Q-00CN-ST0 (dual QSFP112; default 400GbE / NDR InfiniBand). Always freeze the exact OPN, cage and default protocol on the RFQ line.
Datasheet host interface is PCIe Gen6 (up to 48 lanes). Putting CX8 into a Gen5-only slot wastes the host path even if the network port is 800G-capable. Confirm motherboard/riser generation before you award the NIC line.
Possible on paper, painful in operations. Different cages, optics kits and driver/firmware baselines multiply spare parts. Prefer one NIC generation per plane unless the architecture document explicitly dual-homes generations.
Yes. Send topology and target Gb/s per link. We mark which lines need CX8 and which stay on CX7 within 1 business day. Lead times and prices pending confirmation.
References
Quick Answer: Buyer behaviour figures come from the G2 and TechnologyMatch 2026 surveys; tender scale from DoNews award tracking for the first seven months of 2026. Checked 21 October 2026.
Key Takeaway
Key Takeaway: Choose ConnectX-8 when the fabric or host path needs 800 Gb/s / Gen6; keep ConnectX-7 when the design is still 400 Gb/s Gen5. Freeze OPN and cage on the RFQ. BENQUAN maps CX7 vs CX8 in 1 business day; prices and lead times pending confirmation.