Data Center Networking / Optics / Cabling / Specs / Procurement

DR 500m or FR 2km: Which SMF Optic?

One matrix for the single-mode ladder — QSFP-100G-DR/FR, QDD-400G-DR4/FR4, QDD-800G-2FR4/2XDR4. Reach classes, fiber and connector types, breakout interop, spares math, and how to structure the optics RFQ.

Quick Take

Quick Take: The Arista single-mode optics ladder covers QSFP-100G-DR/FR at 100G, QDD-400G-DR4/FR4 at 400G, and QDD-800G-2FR4/2XDR4 at 800G. DR optics reach 500 meters, FR reaches 2 kilometers. Choose DR for intra-building links, FR for campus backbone. All models support 100G breakout over single-mode fiber, simplifying migration from 100G to 400G/800G infrastructure.

When to Use This Matrix

Quick Answer: Use this matrix when a BOM mixes 100G, 400G, and 800G ports across rooms and buildings on single-mode fiber. It decodes the DR, FR, DR4, FR4, 2FR4, and 2XDR4 suffixes, their reach and connectors, and which pairs interoperate. Multimode VSR4 optics live in the companion guide.

Optics suffixes fail silently at PO time: DR and FR look interchangeable on a spreadsheet, parallel and duplex trunks do not mate, and CS connectors at 800G are missing from most cabling inventories. At five-digit optic quantities, one wrong suffix is a six-month schedule slip.
3
Speed Tiers (100/400/800G)
500 m
DR-Class Reach
2 km
FR-Class Reach
4x
DR4 to 100G-DR Breakout

The Full SMF Matrix: Reach, Fiber, Connectors

Quick Answer: Reach and media decide everything: DR-class optics run 500 meters on parallel or duplex single-mode; FR-class optics run 2 kilometers. Connectors split three ways — LC duplex at 100G and 400G-FR4, MPO-12 for parallel DR4 and XDR4, dual CS uniquely on QDD-800G-2FR4.

Part number Standard Reach Fiber Connector
QSFP-100G-DR100GBASE-DR500 mDuplex SMFLC
QSFP-100G-FR100GBASE-FR2 kmDuplex SMFLC
QDD-400G-DR4400GBASE-DR4500 mParallel SMF (8 fibers)MPO-12
QDD-400G-FR4400GBASE-FR42 kmDuplex SMFLC
QDD-800G-2FR42x 400GBASE-FR42 kmDual duplex SMFDual CS
QDD-800G-2XDR42x 400GBASE-XDR42 kmParallel SMFDual MPO-12

How to read the suffixes

DR = 500 m reach class, PAM4 per-lambda; FR = 2 km reach class; a trailing 4 means four lanes (parallel or WDM); a leading 2 at 800G means two independent 400G channels in one module. Reach is a class ceiling, not a target — a 60 m hall-to-hall run on DR optics is normal and saves the FR premium.

Breakout & Interop Rules

Quick Answer: Same-standard ends always link: DR4 to DR4, FR4 to FR4. The workhorse combination is QDD-400G-DR4 breaking out to four QSFP-100G-DR over parallel single-mode, which is how 100G server rows uplink into 400G spines. Never mix DR with FR or single-mode with multimode on one span.

A-end B-end Works? Note
QDD-400G-DR4QDD-400G-DR4YesPoint-to-point 400G, MPO-12 trunk, 500 m
QDD-400G-DR44x QSFP-100G-DRYesMPO-12 to 4x LC breakout — the 100G-to-400G migration pattern
QDD-400G-FR4QDD-400G-FR4YesDuplex LC trunk, 2 km
QDD-800G-2FR42x QDD-400G-FR4YesTwo independent 400G-FR4 channels via CS-to-LC cabling
QDD-400G-DR4QDD-400G-FR4NoDifferent standards — DR4 is parallel, FR4 is WDM duplex
Any DR/FR (SMF)Any VSR4 (OM4)NoFiber types never mix — see the VSR4 multimode guide

Why DR + DR4 dominates 100G-heavy estates

A 100G leaf estate uplinking into 400G spines wants one optic family with one reach class: QSFP-100G-DR at the leaf, QDD-400G-DR4 at the spine, MPO-12 breakout trunks between. One spare pool, one polarity plan, and every link stays inside the 500 m budget of a large hall.

The 800G Fork: 2FR4 vs 2XDR4

Quick Answer: QDD-800G-2FR4 behaves as two independent 400G-FR4 channels on dual CS connectors over duplex single-mode; QDD-800G-2XDR4 carries the same two channels on dual MPO-12 parallel fiber. Choose by fiber plant and patch-panel format, not price alone, and confirm CS-connector patch cords exist in your inventory.

  • Duplex plant (LC/CS patch panels): QDD-800G-2FR4 — but audit patch-cord stock, because CS connectors are new to most sites
  • Parallel plant (MPO trunks): QDD-800G-2XDR4 — reuses the same MPO-12 discipline as DR4 estates
  • Typical seat: 800G router and super-spine ports — for example the DCS-7280R4K-32DE-F — splitting into two 400G links toward spine or peer devices
  • Discipline: each 400G channel follows normal FR4/XDR4 interop rules; label both sub-channels on the patch panel from day one

RFQ Checklist for SMF Optics Lines

Quick Answer: Quote every transceiver as its own line with speed, reach suffix, and connector type, then attach a span table that proves each link fits DR at 500 m or FR at 2 km. Add 2 to 3 percent spares per optic type, and demand dated quarterly availability alongside the switch schedule.

What to put on the optics RFQ

  • Per-line quantities: QSFP-100G-DR / QSFP-100G-FR / QDD-400G-DR4 / QDD-400G-FR4 / QDD-800G-2FR4 / QDD-800G-2XDR4
  • Span table: longest run per link class, confirming DR (500 m) vs FR (2 km) assignment
  • Fiber plant: duplex vs parallel trunks per span; MPO polarity plan for DR4/XDR4
  • Connector inventory: LC, MPO-12, and CS patch cords per site
  • Breakout lines: MPO-12-to-LC assemblies for DR4-to-4x100G-DR fans
  • Spares: 2-3% per optic type per site, stated as separate lines
  • Dated availability per quarter, on the same calendar as switch delivery
  • Coding note: optics matched to Arista platforms on the same BOM

Verify part numbers on SKU Lookup, then submit per-line quantities on rfq.html.

Frequently Asked Questions

Quick Answer: Buyers ask five things about this ladder: the practical difference between DR and FR reach classes, whether 400G-DR4 really breaks out to four 100G-DR links, how the two 800G formats differ, whether single-mode and multimode ever mix, and how to source everything on one dated calendar.

Reach: QSFP-100G-DR runs up to 500 meters, QSFP-100G-FR up to 2 kilometers, both single-lambda 100G over duplex single-mode with LC connectors. Same speed, same fiber — pay the FR premium only on spans that actually exceed 500 meters.

Yes. 400GBASE-DR4 is four 100G PAM4 lanes on parallel single-mode, so one QDD-400G-DR4 fans out over an MPO-12-to-LC breakout into four QSFP-100G-DR links up to 500 meters. It is the standard 100G-leaf to 400G-spine uplink pattern.

Both carry two 400G channels up to 2 km. 2FR4 uses duplex single-mode with dual CS connectors; 2XDR4 uses parallel single-mode on dual MPO-12. Pick whichever matches your existing patch panels and trunk type; CS patch cords are the item most sites lack.

No. Both ends must match standard and fiber: DR/FR families run on single-mode, VSR4 runs on multimode OM4. For in-room 400G links under 50 meters, the multimode VSR4 pair is usually the cheaper answer — see the companion VSR4 guide.

Submit per-line quantities through the RFQ desk for dated availability.

Key Takeaway

Key Takeaway: One ladder, two questions per span: how far (DR 500 m vs FR 2 km) and which connector (LC, MPO-12, or CS). Get those right and 100G-to-800G migrations reuse one single-mode plant. BENQUAN GLOBAL LIMITED supplies Arista 100G, 400G and 800G single-mode optics with competitive pricing.

Ordering single-mode optics at four or five-digit quantities?

If DR-versus-FR assignments, breakout plans, or CS-connector inventory on your optics BOM are unconfirmed — or transceiver lead times are quoted apart from the switches — click below for a free compatibility and delivery risk assessment.

Free Compatibility & Delivery Risk Assessment